Therapy Equiment-Blood Pressure Monitor
| Offer Type: |
|
|---|---|
| Offer Post Time: | 2009-11-08 |
| Expiration Date: | 2009-12-26 |
| Details: |
Size: 70mm*72mm*23mm
Product Features * Intelligent automatic compression and decompression * At the same time, systolic blood pressure measurements, blood pressure and pulse * Easy, simply by switching button can be tested * 60 store group memory measurements * Can be found in a single or all of the measurements * 3 minutes automatic power saving device * Intelligent device debugging, automatic power to detect * Local tests for: Wrist circumference to 135 ~ 195mm * The number of large-scale LCD screen * High-accuracy Usage Install or replace the battery 1, the battery is installed: According to the battery cover the direction of the arrow to open the battery cover, according to an internal battery (+), (-) marked symbols into 2 AAA alkaline batteries, and then slide the battery cover close. 2, to replace the battery: The machine will automatically detect the power to display symbols appear when the power shortage, said the lack of electricity, re-confirmed that the battery polarity, or the immediate replacement of 2 new AAA alkaline batteries, or will not be able to feel the pulse and blood pressure measurements, and with sphygmomanometer Storage of measurements and time settings will be lost. With the use of the wrist 1, palms up, blood pressure monitors are also facing upward, and with the wrist wrapped in from the left wrist joints 5 ~ 10mm Office (about one finger width). 2, to seize the wrist band at the end of the following, and pulling in the same time, their wrists tied to the volume, stick to up Guoshang strain, wrist strap and not to leave gaps between. 3, wrist band too long, can be properly fixed anti-fold. Measuring the correct posture Sitting to be measured, can be left on the table, or in accordance with the actual demand increases blood pressure pad incorporated or pillow case, the pressure to adjust the location of the wrist band. The pad can add items to bring down the wrist, so as not to affect the measurement values. How to measure blood pressure In order to understand your blood pressure, blood pressure measuring a fixed time every day. Please refer to the measurements before the "pre-measured", "wrist band to use", "Measuring the correct posture, " and so on. 1, with wrists tied to the wrist, palms up will be relaxed so that the wrists with the location of the heart and with the high. 2, according to the power supply to open the key to open. The screen shows all the signs will be like when the screen flashes numbers 0 to stop, to start measuring. 3, and then click open the key to start measuring, and wrist band into the air around 180mmHg blood pressure in the inflatable screen will appear when the inflatable symbol (measured in Yaoshou or do not speak). 4, after the completion of the pressure, the pressure will gradually decline, measured after the pulse, heart-shaped symbol will begin flashing simultaneously with the heartbeat. (Note: If possible high blood pressure, blood pressure may be discouraged to stop, and will automatically pump pressure to the ideal pressure). To read the measurement value 1, automatic storage of measurements Every time measurement is completed, the machine automatically stored measurements of systolic blood pressure, pulse and blood pressure, can store up to the old measurements will be automatically deleted and replaced by the latest measurements. 2, to read a single measurement: Under normal conditions, according to the memory keys to read the latest measurements (systolic pressure, diastolic blood pressure and pulse a few), then click the button memory can be read in the next set of data, according to repeat the key memory storage in order to read the information. (M01, said the latest measurements, M02, said last second measurements, and so on). |
Most Popular
-

Armipt Thermometer Armipt Thermometer Class: Thermometers For Human ... -

Dental Unit (XH-E103) XH-E103 Dental Unit STANDARD ACCESSORIES ... -

Babysound-B Fetal Doppler - CE Approved CONTEC is one of the biggest professional ...
-

CCT Direct Selling Aids Computer is not included How does CCT Human ... -

X- Ray Machine (100mA) USE General Photograpy, Filte-ray device ... -

Stethoscope *Single Head Stethoscope *Anodized aluminum ...
-

Stainless Steel Stethoscope Specification: CE, ISO *with uniquely ... -

Blood Pressure Monitor (KD-737) Display system: Extra-large LCD with digital ... -

ECG (ET-3A) FEATURES: Synchronously acquisition of 12-lead ...
-

URIT 2900 Automated Hematology Analyzer *Sample Volume: Whole blood 10uL, Pre-diluent ... -

Intra Oral Camera System (Endoscope ZC-2001) INTRODUCTION: 1. This equipment is composed of ... -

Rechargeable Ophthalmoscope (Kj8b) Characteristics: Perfect optics system offers ...
-

Dental Surgical Microscope ALLTION AM-3000 series Surgical Microscopes offer ... -

X Ray Machine Dear sir, We Are A Good Supllier for medical x ... -

Patient Monitor (G3D) 1. Displayer: 12.1' color TFT LCD screen with ...
Related Searches |
Inquiry Basket (




